Print Certificate
Certificate
Lactic acid USP/Ph.Eur/BP PARENTEX 2.5LT
P0808LC25038439B202HV
USP/Ph.Eur/BP PARENTEX38439B2
79-33-487359
C3H6O3August 2022
90.1July 2025
Sr.No.TestResultSpecification
1Appearance/DescriptionColorless syrupy liquid.Colorless or slightly yellow, syrupy liquid.
2SolubilityCompliesInsoluble in chloroform;Miscible with water, Alcohol and with ethanol (96%)
3Identification (By chemical test)CompliesThe solution should be strongly acidic.
4Identification (by Relative density, 20°C)1.201.20 to 1.21
5Identification (Lactate)CompliesA blue color should produce.
6Appearance of solutionCompliesThe solution should not be more intensely colored than reference solution Y6.
7Assay90.3%88.0% - 92.0% w/w
8Sulphated ash / Residue on ignition0.02%NMT 0.05%
9Sugars and other reducing substancesCompliesNo red or greenish precipitate should form.
10Calcium (Ca)Less than 200 ppmNMT 200 ppm
11Sulphate (SO4)Less than 200 ppmNMT 200 ppm
12Sulphate(SO4)CompliesNo turbidity should produce.
13Ether insoluble substancesCompliesThe solution should not more opalescent than the solvent used for the test.
14Citric, oxalic and phosphoric acidsCompliesAny opalescence produced in the sample solution should not be more intense than that of reference solution.
15Limit of citric, oxalic, phosphoric or tartaric acidCompliesNo turbidity should produce.
16Chloride (Cl)CompliesNo opalescence should produce.
17Readily carbonizable substancesCompliesNo dark color should develop at the interface of the two acid within 15 min.
18SugarsCompliesNo red precipitate should form.
19Methanol(CH3OH)Not detectedNMT 50 ppm
20Bacterial endotoxin testLess than 5.0 EU/gmNMT 5.0 EU/gm
Remarks: THE CAPTIONED BATCH MATERIAL COMPLIES WITH THE PRESCRIBED QUALITY OF THE ABOVE SPECIFICATION AS WELL AS USP, Ph.Eur, BP SPECIFICATION.
FINAR provides this analytical report in good faith and to the best of its knowledge. It should not be substituted for the users own raw material quality control.
Tested By
(Chemist - Quality Control)
Approved By
(Head - Quality Control)
Computer Generated Report - Does not require Signature.
Print Certificate