Print Certificate
Certificate
Lactic acid USP/Ph.Eur/BP PARENTEX 2LT
P0808LC20043029B228BX
USP/Ph.Eur/BP PARENTEX43029B2
79-33-4102094
C3H6O3February 2024
90.1January 2027
Sr.No.TestResultSpecification
1Appearance/DescriptionColorless, syrupy liquid.Colorless or slightly yellow, syrupy liquid.
2SolubilityCompliesInsoluble in chloroform;Miscible with water, Alcohol and with ethanol 96%
3Identification (By chemical test)CompliesThe solution should be strongly acidic.
4Identification (by Relative density, 20°C)1.211.20 to 1.21
5Identification (Lactate)CompliesA blue color should produce.
6Appearance of solutionCompliesThe solution should not be more intensely colored than reference solution Y6.
7Assay89.4%88.0% - 92.0% w/w
8Sulphated ash / Residue on ignition0.006%NMT 0.05%
9Sugars and other reducing substancesCompliesNo red or greenish precipitate should form.
10Calcium (Ca)Less than 200ppmNMT 200 ppm
11Sulphate (SO4)Less than 200ppmNMT 200 ppm
12Sulphate(SO4)CompliesNo turbidity should produce.
13Ether insoluble substancesCompliesThe solution should not more opalescent than the solvent used for the test.
14Citric, oxalic and phosphoric acidsCompliesAny opalescence produced in the sample solution should not be more intense than that of reference solution.
15Limit of citric, oxalic, phosphoric or tartaric acidCompliesNo turbidity should produce.
16Chloride (Cl)CompliesNo opalescence should produce.
17Readily carbonizable substancesCompliesNo dark color should develop at the interface of the two acid within 15 min.
18SugarsCompliesNo red precipitate should form.
19Methanol(CH3OH)Not detectedNMT 50 ppm
20Bacterial endotoxin testLess than 5.0 EU/gmNMT 5.0 EU/gm
Remarks: THE CAPTIONED BATCH MATERIAL COMPLIES WITH THE PRESCRIBED QUALITY OF THE ABOVE SPECIFICATION AS WELL AS USP, Ph.Eur, BP,SPECIFICATION.
FINAR provides this analytical report in good faith and to the best of its knowledge. It should not be substituted for the users own raw material quality control.
Tested By
(Chemist - Quality Control)
Approved By
(Head - Quality Control)
Computer Generated Report - Does not require Signature.
Print Certificate