Print Certificate
Certificate
tert-Butanol HP PARENTEX PLUS 5LT
I4334LC50042177B328JW
HP PARENTEX PLUS42177B3
75-65-099290
C4H10OOctober 2023
74.12September 2025
Sr.No.TestResultSpecification
1Description (Colour)Clear, colourless liquidClear, colourless liquid
2Description (Form)Clear liquidSolidified mass or clear liquid
3Description (Odour)CompliesHas a camphoraceous odour
4Identification by IR spectraCompliesIR spectra of the sample should be concomitant with IR spectra of the standard.
5MiscibilityCompliesThe solution should be clear and colourless.
6Colour (APHA)Less than 10 HzNMT 10 Hz
7Carbonyl compound as AcetoneNot detectedNMT 100ppm
8Carbonyl compound as AldehydeCompliesThe diffrence between blank and sample Not more than 1.75ml 0.1N iodine
9Propylene glycol contentNot detectedNMT 50ppm
10Residue on evaporation0.0006%NMT 0.001%
11Boiling range82.5-83.5°C82.5°-83.5°C
12Water (By KF)0.02%NMT 0.1%
13Readily oxidizable substancesCompliesThe Permanganate color of the mixture does not completely disappear with in 15 mins.
14Specific gravity, 25°C0.782g/cm30.780-0.790 g/cm3
15Purity (By GC)99.97%NLT 99.7%
162-Butanol61 ppmNMT 1000ppm
17Acidity15ppmNMT 30ppm
18Alkalinity4.3ppmNMT 10ppm
19UV absorbance profile (10mm cell)@215nm0.521NMT 1.0
20UV absorbance profile (10mm cell)@250nm0.020NMT 0.2
21UV absorbance profile (10mm cell)@300nm0.000NMT 0.01
22Total Peroxide18ppmNMT 40ppm
23Freezing point25.3°CNLT 25°C
24Arsenic (As)Not detectedNMT 0.15ppm
25Cadmium(Cd)Not detectedNMT 0.2ppm
26Lead (Pb)Not detectedNMT 0.5ppm
27Mercury(Hg)Not detectedNMT 0.15ppm
28Hydrogen peroxideLess than 5 ppmNMT 5ppm
29Total aerobic bacterial countLess than 100 CFU/mlNMT 100 CFU/ml
30Total combined yeast and molds countLess than 100 CFU/mlNMT 100 CFU/ml
31E.coliAbsent/mlshould be absent/ml
32SalmonellaAbsent/10mlshould be absent/10 ml
33Pseud. aeruginosaAbsent/mlshould be absent/ml
34Staphylococcus aureusAbsent/mlshould be absent/ml
35Bile-tolerant gram negative bacteriaAbsent/mlshould be absent/ml
36Bacterial endotoxinsLess than 6 EU/mlNMT 6 EU/ml
Remarks: THE CAPTIONED BATCH MATERIAL COMPLIES WITH THE PRESCRIBED QUALITY OF THE ABOVE SPECIFICATION.
FINAR provides this analytical report in good faith and to the best of its knowledge. It should not be substituted for the users own raw material quality control.
Tested By
(Chemist - Quality Control)
Approved By
(Head - Quality Control)
Computer Generated Report - Does not require Signature.
Print Certificate