Print Certificate
Certificate
Benzyl Benzoate USP/Ph.Eur/BP PARENTEX PLUS 2LT
I0293LC20040130B115BW
USP/Ph.Eur/BP PARENTEX PLUS40130B1
120-51-492502
C6H5COOCH2C6H5February 2023
212.2January 2025
Sr.No.TestResultSpecification
1DescriptionClear, colorless, oily liquid having a slight aromatic odor.Clear, colorless, oily liquid having a slight aromatic odor.
2SolubilityCompliesPractically insoluble in water and in glycerin. Miscible with alcohol, Ethanol (96%), with ether, and with chloroform with methylene chloride and with fatty and essential oils.
3Identification A (By IR)CompliesIR Spectra of the sample should be concomitant with IR spectra of the standard
4Identification B (By Chemical test)CompliesDried precipitate should melt between 121°C to 124°C
5Identification C (By Chemical test)CompliesDried precipitate should melt between 121°C to 124°C
6Assay99.8%99.0% - 100.5%
7Limit of Aldehydes0.03%NMT 0.05% (as benzaldehyde)
8Specific gravity, 25°C1.1171.116 to 1.120
9Relative density, 20°C1.1191.118 to 1.122
10Congealing temperature19°CNLT 18.0°C
11Freezing point18.0°CNLT 17.0°C
12Refractive index,20° C1.5691.568 - 1.570
13AcidityCompliesNMT 1.5ml of 0.020N sodium hydroxide should require to restore the pink color.
14Boiling point322°CAbout 320°C
15Sulphated ash0.04%NMT 0.1%
16Total aerobic microbial countLess than 100 CFU/mlNMT 100 CFU/ml
17Total combined yeast and molds countLess than 10 CFU/mlNMT 10 CFU/ml
18Bacterial endotoxinsLess than 0.25 EU/mlNMT 0.25 EU/ml
19Escherichia coliAbsent/mlshould be Absent/ml
20SalmonellaAbsent/10mlshould be Absent/10ml
21Staphylococcus aureusAbsent/mlshould be Absent/ml
22Pseud. aeruginosaAbsent/mlshould be Absent/ml
Remarks: THE CAPTIONED BATCH MATERIAL COMPLIES WITH THE PRESCRIBED QUALITY OF THE ABOVE SPECIFICATION AS WELL AS USP, Ph.Eur, BP SPECIFICATION.
FINAR provides this analytical report in good faith and to the best of its knowledge. It should not be substituted for the users own raw material quality control.
Tested By
(Chemist - Quality Control)
Approved By
(Head - Quality Control)
Computer Generated Report - Does not require Signature.
Print Certificate