Print Certificate
Certificate
Butylated Hydroxyanisole USP-NF/Ph.Eur 1KG
97370SR10043256H609DX
USP-NF/Ph.Eur43256H6
25013-16-5102608
C11H16O2April 2024
180.25March 2027
Sr.No.TestResultSpecification
1Appearance/DescriptionWhite crystalline powder, having a faint, characteristic odor.White or yellowish / slightly yellow or slightly pinkish waxy solid or crystalline powder, having a faint, characteristic odor.
2SolubilityCompliesFreely soluble in alcohol, in propylene glycol, in chloroform and in ether, and in fatty oils. Practically insoluble in water. very soluble in methylene chloride. It dissolves in dilute solutions of alkali hydroxides.
3Identification (By IR)CompliesAll peak positions determined for butylated hydroxyanisole are within 5cm-1 of those determined for 3-tert-Butyl-4-hydroxyanisole standard.
4Identification (By Chromatography)CompliesThe retention time of the main peak of the sample solution corresponds to that of the standard solution. The chromatographic profile of the sample solution similar to that of the standard solution and exhibit only 1 major peak corresponding to BHA.
5Identification (By TLC)CompliesThe principal spot in the chromatogram obtained with test solution (b) is similar in position, color and size to the principal spot in the chromatogram obtained with reference solution (a).
6Identification (By chemical test 1)CompliesAfter separation, the organic layer is red.
7Identification (By chemical test 2)CompliesA red color develops.
8Assay(HPLC)99.51%NLT 98.5%
9Appearance of SolutionCompliesSolution is clear and not more intensely colored than intensity 5 of the range of reference solutions of the most appropriate color.
10Related substances By TLC (3-(1,1-Dimethylethyl)-4-methoxyphenol)Less than 10.0%NMT 10.0%
11Related substances By TLC (Hydroquinone)Less than 0.2%NMT 0.2%
12Related substances By TLC (Any other impurity)Less than 0.5%NMT 0.5%
13Residue on ignition /Sulfated ash0.002%NMT 0.01%
14Residual solvent as n-Hexane24 ppmNMT 200ppm
Remarks: THE CAPTIONED MATERIAL COMPLIES WITH THE PRESCRIBED QUALITY OF USP-NF AND PH.EUR SPECIFICATION.
FINAR provides this analytical report in good faith and to the best of its knowledge. It should not be substituted for the users own raw material quality control.
Tested By
(Chemist - Quality Control)
Approved By
(Head - Quality Control)
Computer Generated Report - Does not require Signature.
Print Certificate