Print Certificate
Certificate
Acetone CDMF 2.5LT
93020LC25035293D223GU
CDMF35293D2
67-64-176699
CH3COCH3July 2021
58.08June 2024
Sr.No.TestResultSpecification
1Appearance/DescriptionTransparent, colorless, mobile, volatile liquid, having a characteristic odor. A solution (1 in 2) is neutral to litmus.Transparent, colorless, mobile, volatile liquid, having a characteristic odor. A solution (1 in 2) is neutral to litmus. (USP/Ph.Eur)
2SolubilityPassesMiscible with water, with alcohol, with ether, with chloroform, and with most volatile oils. (USP/Ph.Eur)
3Appearance of solutionPassesClear and colorless solution (Ph.Eur)
4Identification (By IR)CompliesIR Spectra of the sample should be concomitant with IR spectra of the standard (USP)
5Identification (by Chromatogram)CompliesThe retention time of the sample corresponds to that of standard obtained in the assay (USP)
6Identification (Relative density, 20°C)0.7910.790 - 0.793 (Ph.Eur)
7Identification (By chemical test 1)CompliesAn intense red color should produce which becomes violet with the addition of 3.5 mL of acetic acid (Ph.Eur)
8Identification (By chemical test 2)CompliesA greenish-blue color should produce (Ph.Eur)
9Relative density, 20°C0.7910.790 - 0.793 (Ph.Eur)
10Assay (GC)99.97%NLT 99.0% on the anhydrous basis. (USP)
11Specific gravity,25°C0.788NMT 0.789 (USP)
12Non-volatile Residue0.0006%0.004% max (USP)
13Matter insoluble in waterCompliesThe solution should be clear (Ph.Eur)
14Water2.44g/l3g/l max (Ph.Eur)
15Reducing substancesCompliesThe mixture should not be completely decolorised (Ph.Eur)
16Acidity or AlkalinityCompliesThe solution should be red or orange (Ph.Eur)
17Related substances: Impurity A (Methanol)0.02%0.05% v/v max (Ph.Eur)
18Related substances: Impurity B (2-Propanol)Not detected0.05% v/v max (Ph.Eur)
19Related substances: Impurity C (Benzene)Not detected2 ppm v/v max (Ph.Eur)
20Related substances: Any other impurity0.001%0.05% v/v max (Ph.Eur)
Remarks: THE CAPTIONED BATCH MATERIAL COMPLIES WITH THE PRESCRIBED QUALITY OF THE ABOVE SPECIFICATION AS WELL AS USP-NF, Ph.Eur SPECIFICATION.
FINAR provides this analytical report in good faith and to the best of its knowledge. It should not be substituted for the users own raw material quality control.
Tested By
(Chemist - Quality Control)
Approved By
(Head - Quality Control)
Computer Generated Report - Does not require Signature.
Print Certificate